Pactrol P25 Control Module 052193

Meta

Title: Pactrol P25 Control Module 052193 | Hot Water Supplies

Description: This Rheem hot water control module will suit any 631275 models manufactured from 1st April 2005. Find hot water system parts online with Hot Water Supplies today.

Content

052193 Pactrol P25 Control Module

Please note: We highly recommend a professional install this part in order to comply with health and safety standards and to avoid injury to yourself or your property.

As of September 2015, all 631275 HD gas storage models will be fitted with this Pactrol P25 ‘F’ HSI FMV ignition module with 052193 part number. Supplied as a spare part, it is a direct replacement for the White Rodgers 50A72-178 and suits any 631275 models manufactured from 1st April 2005.

The 052193 Pactrol P25 Control Module is mounted in an identical way to the White Rodgers module, with no adjustments needed. We do recommend replacing the front cover  (part number 108335) at the same time as this pactrol module when fitting it in an existing 621275 & 622275 water heater, as the viewing window in the heater front cover will be obstructed. This is particularly important for those manufactured before 18th September 2015.

The features that have been modified in this 052193 Pactrol P25 control module compared to the White Rodgers are:

  • There are no display specific fault codes for fault conditions
  • There’s two ignition retries, meaning a total of three ignition attempts and a five-minute delay between each attempt
  • The module will go into lockout mode if resistance is not detected through the gas valve circuit. Important note: on 631275 models if the lower access door is removed, the door switch breaks the gas valve circuit which will result in lockout mode instigating
  • This module doesn’t check the igniter circuit. If your igniter is open circuit, the module will progress through sequence of operation and will lockout after three ignition attempts
  • The Pactrol P25 Control Module has a volatile memory. If you turn power off and on at the power point, it will reset both models of the ignition module but there is also a reset button on the ignition module.

Product Data

Title: Pactrol P25 Control Module 052193

Short Description

This Rheem Pactrol P25 Control Module provided by Hot Water Supplies and is a direct replacement for the White Rodgers 50A72-178.